CONTACT US
service@zero-ground.com
HFES® 866-937-6463
dBzSHIELD® 401-377-8389

TECHNICAL TOOLS & RESOURCES
All Technical Information
Technical Data Sheets
dBzSHIELD Test Report
How to Specify dBzSHIELD

MARKETS & APPLICATIONS
Defense & Government
Commercial & Industrial

PRODUCTS
dBzSHIELD Flex Conduits
dBzAdapter Fittings

TERMINATION SOLUTIONS
Review Termination Options

CUSTOMER SERVICE
Sales & Technical Support
Request a Free Sample
Get Technical Updates
Authorized Resellers

OTHER ZERO GROUND PRODUCT LINES
Zero Ground HFES®

ZERO GROUND LLC
dBzSHIELD Sales Office
401-377-8389 TEL
service@zero-ground.com

ZERO GROUND LLC
Main Office
HFES Sales Office
3392 Hillside Ct.
Woodridge, IL 60517-1438
866-937-6463 (toll-free)
630-968-1200 (fax)
engineering@zero-ground.com


All ZERO GROUND products are Made in the USA

Cage Code 4GXD9
Quantity discounts available

 

TERMINATION SOLUTIONS
(Enclosure, NO Enclosure, Direct to Military Connector)

USING ENCLOSURE

dBzSHIELD's family of shielded (screened) Liquid Tight Flex Conduits are designed to accept commercial liquid tight metallic conduit fittings with NPT (National Pipe Thread) threads. These fittings typically terminate to a metal enclosure or bulkhead. A locknut inside the enclosure secures the fitting.

Fitting Options from left: 45 degree into enclosure, external ground lug, added strain relief, dBzAdapter for Mil 38999
45 degree fitting external ground lug added strain relief 38999 dBzAdapter

TERMINATIONS NOT USING ENCLOSURE

The challenge of termination without an enclosure is to provide sufficient strain relief for the cable as it exits the conduit fitting, and to support the weight of the terminating connector or device. Both of these objectives can be met by combining two alternative connecting components.
1) Combination fitting/adapter with female NPT threaded end attaches to dBzSHIELD
2) Mating cord grip with male NPT threaded end attaches to combination fitting/adapter.
Many variations are commercially available for both of these components. Please contact us for assistance in identifying the desired features for your termination.

Selected Fitting Manufacturers (Online catalog link goes directly to Liquid Tight Conduit Fittings Section)

Thomas & Betts

www.tnb.com Vendor Catalog Link

Consult Zero Ground's listing of Thomas & Betts fittings catalog numbers

Bridgeport Fittings

www.bptfittings.com Vendor Catalog Link

American Fittings

www.americanfittingscorp.com Vendor Catalog Link

NEW! Additional sources of NPT, ISO PG and ISO Metric fittings are available. Download pdf: Online Specification Resource Guide, including Termination Components and Supplies Sources.

 

KEY STANDARD NPT FITTING COMPONENTS

Grounding ferrule

Threads into the internal metallic material of the conduit core. Protects the cut conduit end. The grounding ferrule to internal core connection creates a direct shield-to-drain or ground when fitting body is completely assembled and tightened.

Sealing ring

Slides onto conduit prior to installation of grounding ferrule. Aids in directing liquids away from fitting.

Fitting body and Rear Lock Nut

These pieces thread together to enclose the grounding ferrule and sealing ring. Tighten per manufacturer's recommendations. The fitting body has a male threaded NPT end.

Enclosure Locknut

For attachment of fitting body to interior of enclosure. Tighten per manufacturer's recommendations.

Typical Fitting Material

Steel with zinc plating. Premium metals are available; selection varies by manufacturer.

Recommended option

Fittings with insulated throat for ease of cable insertion.

Other options

45 degree and 90 degree angled fitting.
Straight, 45 degree and 90 degree angled fitting with integrated external grounding lug.
Bonding rings
Permanent crimp grounding ferrule.
Female NPT thread, with or without integrated external grounding lug.
Metric PG or Metric ISO threads.
Wiremesh grips for added strain relief.
Cushioned clamps.

Assembly of NPT fitting

 

USING dBzAdapter WITH MIL SPEC CONNECTOR

The dBzAdapter line of mil grade adapters has been developed for direct connection of dBzSHIELD to a military connector. Please see the ADAPTER PRODUCTS section of our website for more information, or download the dBzAdapter Datasheet.

Click here to request the dBzAdapter Entry and Interface Specification Catalog by email.

 

Use of Conductive Grease

Fittings are a potential source of leakage. Use of silver conductive grease is recommended. Zero Ground's shield effective testing is conducted using silver conductive grease with NPT fittings.

Examples include:
CHO‐LUBE 4420 (www.chomerics.com)
MG Chemicals 8463 (www.mgchemicals.com)
Chemtronics CW7100 (www.chemtronics.com)

Preparation and Cutting, NEC Conduit Fill Chart

Download pdf: Cutting and Conduit Fill

 

Website Links:
Technical Tools and Resources
dBzSHIELD Product Line
dBzAdapter Product Line
Termination Solutions
Defense & Government Markets and Applications
Commercial & Industrial Markets and Applications
Customer Service

Return to Home Page

 

TRADEMARK INFORMATION:

Zero Ground, BBS, EMSP, IBC, L-BBS, L-IBC, L-SBS, LAS, SBS, ZHLAS, ZHEMSP, dBzSHIELD are registered trademarks of Zero Ground LLC. dBzADAPTER is a trademark of Zero Ground LLC. All rights reserved.

 

   
  RETURN TO THE HOME PAGE
   
  © 1998-2012 Zero Ground. All rights reserved.
For more information, please see our legal and privacy statement.