CONTACT US
service@zero-ground.com
HFES® 866-937-6463
dBzSHIELD® 401-377-8389


ZERO GROUND HFES® INFORMATION LINKS:
Introduction to HFES Powerpoint
Why HFES is the PERMANENT solution
About HFES Development
How HFES Operates
HFES Applications
HFES For Mining Applications
Are These Your Grounding Issues?
HFES Reviews
HFES vs. Standard Wiring Systems
Is ZERO GROUND HFES For You?
ZERO GROUND HFES Press Release

ZERO GROUND HFES SYSTEM SOLUTION PRODUCT INFORMATION:
LOW VOLTAGE (1,000V) PRODUCT INFORMATION
10 HP or Less @ 33 Amps
50 HP or Less @ 70 Amps
125 HP or Less @ 205 Amps
250 HP or Less @ 410 Amps
500 HP or Less @ 820 Amps
Accessories
MEDIUM VOLTAGE (1,000V - 12,000V) PRODUCT INFORMATION

VARIABLE FREQUENCY DRIVE INFORMATION LINKS:
NEW! ABB - Addressing Motor Bearing Currents - 2011

Motor Bearing Currents

VFD Technical Information

Contact ZERO GROUND:

ZERO GROUND LLC
HFES Sales Office
3392 Hillside Ct.
Woodridge, IL 60517-1438
866-ZERO-GND (toll-free)
866-937-6463
630-968-1200 (fax)
engineering@zero-ground.com

ZERO GROUND LLC
dBzSHIELD Conduit Sales Office
401-377-8389
425-930-3626 (fax)
service@zero-ground.com


HFES REPRESENTATIVES:

DCSi, Inc.
Dynamic Commissioning Solutions, Inc.
Las Vegas Office
3078 East Sunset Rd, Suite 5
Las Vegas , NV 89120
Phone: 702-942-1616
Fax: 702-942-1617
Website: www.LV-DCSi.com
E-Mail: kfujimoto@lv-dcsi.com

Los Angeles Office
Wells Fargo Center
333 S. Grand Ave. 25th Floor
Los Angeles, CA 90071
Phone: 888-855-DCSi (3274)


All ZERO GROUND products are Made in the USA

Quantity discounts available


ZERO GROUND HFES® For Mining Applications

The ZERO GROUND® High Frequency Extraction System (HFES), which significantly reduces high frequency VFD generated currents, has been formally approved by the U.S. Dept. of Labor, Mining and Safety Health Administration (MSHA) for use in underground and surface mines located in the United States.

ZERO GROUND HFES has also been approved by the Bureau of Mine Safety, Pennsylvania Department of Environmental Protection, and has been issued a “P” number to be used in conjunction with the MSHA approval number for the ZERO GROUND HFES solution.

MSHA Approval Number: P07-KA070024-MSHA

HFES Offers Unequaled Safety Benefits and Reduces Unplanned Downtime

Variable Frequency Drive (VFD) generated high frequency ground currents are present wherever VFD’s are in use. These damaging VFD generated currents cause arcing, sparking and shocking, and adversely affect the operation and accuracy of sensitive electronic and communications equipment, including environmental sensors used in Mine-Wide Monitoring Systems (MWMS). Although VFD generated currents cannot be eliminated, ZERO GROUND HFES is the only tested and proven cabling and grounding system to reduce VFD generated currents to safe levels, by directing these harmful currents away from hazardous locations and sensitive equipment.

HFES Offering and Resources for Mining Applications
For system cable assembly repair or extension, download Connection Box part number pdf for Bill of Materials and Instructions

HFES System Specification 10HP or Less @ 33AMPS
HFES Cable Assembly Part Number ZH1033
HFES Connection Box Part Number ZH1033-CB1033 (pdf)
   
HFES System Specification 50 HP or Less @ 70 AMPS
HFES Cable Assembly Part Number ZH5070
HFES Connection Box Part Number ZH5070-CB5070 (pdf)
   
HFES System Specification 125 HP or Less @ 205 AMPS
HFES Cable Assembly Part Number ZH125205
HFES Connection Box Part Number ZH125205-CB125205 (pdf)

General Information

The HFES cable assembly is comprised of a cable (inner component) within a flexible metallic tube (outer component), which must be used together.

P07-KA070024-MSHA approval requires Zero Ground marked cable and flexible metallic tube components. No substitutions allowed.

The P07-KA070024-MSHA HFES System is not to be used on permissible equipment.

The Zero Ground HFES System is not to be used where permissible equipment is required.

The Zero Ground HFES Connection Box is not to be used where permissible equipment is required.

 


HFES System Cable Assembly Design**:

UL Listed Materials

Supports link distances in excess of 500 ft.

Assembly rated for use on “Input" to and “Output" from the drive

Simple Terminations

Uses NO active components such as Filters

Uses all Standard Off-The-Shelf Industry Connectors

Installation Method Meets N.E.C. Section 250

 

 

* “ZERO GROUND” and "HFES" are Federal Registered Trademarks. ZERO GROUND patent applied for.

**Complete Specifications Available

   
  RETURN TO THE HOME PAGE
   
  © 1998-2012 Zero Ground. All rights reserved.
For more information, please see our legal and privacy statement.