CONTACT US
service@zero-ground.com
HFES® 866-937-6463
dBzSHIELD® 401-377-8389

TECHNICAL TOOLS & RESOURCES
All Technical Information
Technical Data Sheets
dBzSHIELD Test Report
How to Specify dBzSHIELD

MARKETS & APPLICATIONS
Defense & Government
Commercial & Industrial

PRODUCTS
dBzSHIELD Flex Conduits
dBzAdapter Fittings

TERMINATION SOLUTIONS
Review Termination Options

CUSTOMER SERVICE
Sales & Technical Support
Request a Free Sample
Get Technical Updates
Authorized Resellers

OTHER ZERO GROUND PRODUCT LINES
Zero Ground HFES®

ZERO GROUND LLC
dBzSHIELD Sales Office
401-377-8389 TEL
service@zero-ground.com

ZERO GROUND LLC
Main Office
HFES Sales Office
3392 Hillside Ct.
Woodridge, IL 60517-1438
866-937-6463 (toll-free)
630-968-1200 (fax)
engineering@zero-ground.com


All ZERO GROUND products are Made in the USA

Cage Code 4GXD9
Quantity discounts available

 

Defense and Government Solutions
Zero Ground Cage Code 4GXD9

LSD Class Satellite Dish Ground Equipment

COMMON CABLE INTERFERENCE and MANAGEMENT PROBLEMS

Meeting Application Attenuation Requirements

Power and signal wire and cable are susceptible to interference from adjacent equipment and devices.
Power and signal wire and cable may cause interference with adjacent equipment and devices.
Emissions from one cable are radiating onto an adjacent cable.
Cable shielding (screening) is not adequate, and redesigning the cable is not a preferred solution.
The cable system attenuation requirements include immunity against environmental sources of interference.
Potential sources of interference cover a broad frequency spectrum, including low (KHz) and high (MHz) frequencies.

How dBzSHIELD Can Help

Shielded (screened) flexible metallic core conduit provides physical and electrical isolation
Tested for shielding effectiveness from 10KHz - 18GHz
If using shielded cable, dBzSHIELD supplements cable shielding
Can be integrated only where needed

Installation and Maintenance, Sourcing and Cost Containment

The installation schedule is tight or not flexible.
Maintenance access to cable inside conduit is required.
Low toxicity conduit jacket (sheath) is required
Routing for cables must incorporate curves.
Cables need the physical protection of conduit.
Cable/conduit segment lengths are long or variable
An enclosure will not be used for termination.
Cable must terminate to a military connector.

How dBzSHIELD Can Help

Installs in one half the time of rigid conduit and more quickly than many Mil Spec conduit systems
Uses cost-effective, easy to assemble fittings.
Removable fittings allow for service or replacement of cables; dBSHIELD can be relocated
Longer lengths typically available, which reduces waste and labor/supplies for splices.
Flexible physical protection to accomodate curves in cable routing.
Supports termination inside an enclosure, where no enclosure is used, or directly to a military connector.
Use only where needed to fix problem areas; avoid cable redesign or may allow use of commonly available cable rather than custom cable designs
Standards sizes from 3/8 inch to 2 inch (US Trade Size) with selected products up to 4 inch

 

THE ATTENUATION SYSTEM

dBzSHIELD is a modified Commercial Off the Shelf (COTS) product line. When planning for critical equipment protection, cable runs through Shielded Flexible Conduits are an option to be considered by EMI and Electrical Engineers along with filters, enclosures and other specialized shielding materials as part of the complete attenuation system.

dBzSHIELD INSTALLED BASE

With an installed base in military and government programs,
dBzSHIELD is actively supporting EMI/RFI/EMP suppression systems in

Army, Air Force, Navy, Marines, and Government Agency equipment

Fixed and Mobile applications

Ground Support Facilities

Test fixtures and equipment

Indoor and Outdoor applications

APPLICATIONS

View our selected list of installed Defense and Government applications.

All dBzSHIELD Shielded Flexible Conduits are RoHS and WEEE compliant.
Selected products comply with common combustion and flammability requirements, including Low Smoke and Zero Halogen.

 

TERMINATION OPTIONS

Using Commercial NPT Conduit Fittings, with or without enclosure

Download pdf: NPT Fittings and Sources

Using dBzAdapter to Mil Spec Connector

Download pdf: dBzAdapter Data Sheet

Click here to request the dBzAdapter Entry and Interface Specification Catalog by email.

 

Website Links:
Technical Tools and Resources
dBzSHIELD Product Line
dBzAdapter Product Line
Termination Solutions
Defense & Government Markets and Applications
Commercial & Industrial Markets and Applications
Customer Service

Return to Home Page

 

 

TRADEMARK INFORMATION

Zero Ground, BBS, EMSP, IBC, L-BBS, L-IBC, L-SBS, LAS, SBS, ZHLAS, ZHEMSP, dBzSHIELD are registered trademarks of Zero Ground LLC. dBzADAPTER is a trademark of Zero Ground LLC. All rights reserved.

 

   
  RETURN TO THE HOME PAGE
   
  © 1998-2012 Zero Ground. All rights reserved.
For more information, please see our legal and privacy statement.