ZERO GROUND introduces dBzSHIELD™,
three NEW types of shielded flexible liquidtight conduits designed for
wiring applications requiring shielding effectiveness from Electromagnetic
and Radio Frequency Interference (EMI / RFI)
| dBzSHIELD™
EMI/RFI SHIELDED CONDUITS - FREE SAMPLE OFFER
There
are conduit manufacturers and there are EMI shielding manufacturers,
but Zero Ground is the only company that specializes in EMI-shielded
conduits. So make life easy for yourself! Try a sample, and see
just how effective Zero Ground conduits are, and how easy they
are to install.
Click
here to request your free sample now (please include
name and delivery address). Delivery usually within 7 to 10 days.
|
Choose the dBzSHIELD
construction type that meets your shielding requirements;
SBS™–
Good Shielding
IBC™ – Better Shielding
BBS™ – Best Shielding
These conduits are
used to protect sensitive electronic circuits such as communications,
radar, and data transmission from outside interference or "noise".
The reverse situation is also an issue. Today's Original Equipment Manufacturers
(OEMs) are finding that, if they wish to ship electrical equipment into
the European community, they may need to be in compliance with the European
CE standard, which reduce the allowable amount of EMI/RFI emissions from
electrical apparatus. All dBzSHIELD Shielded Flexible Conduits are RoHS
compliant.
dBzSHIELD Shielded
Flexible Conduits have been designed for Modified Commercial
Off The Shelf (COTS)
applications, offering a lower cost and standard fittings alternative
to high-end mil-spec shielded conduits, which typically require expensive
custom fittings. Complete specifications are available on the links below.
dBzSHIELD Shielded
Flexible Conduits are designed to accept industry standard liquidtight
connectors (ZERO GROUND recommends Thomas & Betts T&B fittings)
and address the problems of assembly and grounding. Connectors of this
type include a grounding ferrule, which contacts the internal metallic
material of the conduit and the connector body. This produces a direct
shield-to-drain or ground, simply by tightening the connector.
All conduits meet
NEC 350 Liquid Tight Flexible Metal Conduit Type LFMC.
Listed below are simple
product descriptions for dBzSHIELD Shielded Flexible Conduits:
Definitions of Product types:
SBS = Flexible Shielded
Steel Conduit with Tinned Copper Braid and PVC Outer Jacket
L-SBS = Flexible
Shielded Steel Conduit with Tinned Copper Braid and Polyurethane Outer
Jacket
IBC = Flexible Shielded
Bronze Conduit with PVC Outer Jacket
L-IBC = Flexible
Shielded Bronze Conduit with Polyurethane Outer Jacket
BBS = Flexible Shielded
Bronze Conduit with Tinned Copper Braid and PVC Outer Jacket (Also known
as ZERO GROUND armor, it is a key component utilized in our HFES™
system solution for VFD’s)
L-BBS = Flexible
Shielded Bronze Conduit with Tinned Copper Braid and Polyurethane Outer
Jacket
(L = Polyurethane
outer jacket)
Click
here to request a data sheet on your choice of dBzSHIELD shielded flexible
conduits by email.
Are
you currently using or evaluating Zero Ground Flexible Shielded Conduits
Types LAS, ZHLAS, EMS or EMSP? Please contact us to discuss availability.
Conduit Trade Sizes*
(inch):
3/8"
1/2"
3/4"
1"
1 1/4"
1 1/2"
2”
*Larger Sizes Available
Upon Request
SHIELDING
EFFECTIVENESS

Please click on image above for a larger image.
The chart
above and table below depict the shielding effectiveness (attenuation
in dBs) of the BBS, IBC and SBS conduits over a spectrum of test frequencies
from 1 MHz to10 MHz Electric field, to 100 MHz to 1 GHz (1000 MHz) Planewave
field. Tests were performed per MIL-STD-285 on 1/2" trade size conduit.
| |
1
MHz |
10
MHz |
100
MHz |
450
MHz |
1
GHz |
| BBS |
127 |
130 |
136 |
116 |
118 |
| IBC |
126 |
122 |
131 |
98 |
97 |
| SBS |
126 |
98 |
75 |
76 |
66 |
| Unshielded Flexible Steel Conduit |
110 |
80 |
53 |
63 |
51 |
dBzSHIELD
Type SBS

Type
SBS is a UL Listed liquidtight flexible steel conduit, augmented with
a tinned copper shielding braid located over the inner steel core and
under its protective PVC jacket. The braid offers a minimum of 90% coverage
resulting in a shielding effectiveness range from 126dB @1 MHz to 66 dB
@ 1GHz.
Email
us to request Type SBS data sheet.
For
dBzSHIELD Shielded Flexible Conduits Trade sizes, Dimensions, Bend Radius
and Weights in INCH-POUND measurements, click here.
For
dBzSHIELD Shielded Flexible Conduits Trade sizes, Dimensions, Bend Radius
and Weights in METRIC measurements, click here.
For
cutting instructions and conduit capacity chart, dBzSHIELD Shielded Flexible
Conduits, click here.
APPLICATION:
-Meets NEC 350 Liquid
Tight Flexible Metal Conduit Type LFMC
-This Conduit is intended for installation in accordance with Article
350 of the NEC (ANSI/NFPA-70)
-Suitable as an equipment grounding conductor per Article 250.118(7).
-Suitable for use in Hazardous Locations: Class I, Div. 2 and Classes
II and III.
-PVC jacket is resistant to a wide variety of Oils, Acids, Alkaline
and Ultraviolet Light. Polyurethane Jacket (ZHLAS) available.
-Listed and marked for Direct Burial and in Poured Concrete
-For a low smoke, low flame spread, zero halogen version, ask for Polyurethane
jacket Type L-SBS
-Accepts Standard Liquidtight Fittings
-Consult factory for CSA information
-ROHS and WEEE compliant
STANDARD COLORS:
Black. Other colors
and jacketing materials available upon request.
WORKING TEMPERATURES:
-20°C to 60°C.
Optional ratings available.
Listed. Conforms to UL360 for liquidtight flexible steel conduit.
dBzSHIELD
Type IBC

Type
IBC has an inner core that is made from a fully interlocked bronze strip.
Even though it does not contain a braided shield, it offers a shielding
effectiveness from 126 dB @ 1MHz to nearly 100dB @ 1GHz. Email us to request
information on compatible metallic brass (nickel-plated) fittings available
for this bronze conduit.
Email
us to request Type IBC data sheet.
For
dBzSHIELD Shielded Flexible Conduits Trade sizes, Dimensions, Bend Radius
and Weights in INCH-POUND measurements, click here.
For
dBzSHIELD Shielded Flexible Conduits Trade sizes, Dimensions, Bend Radius
and Weights in METRIC measurements, click here.
For
cutting instructions and conduit capacity chart, dBzSHIELD Shielded Flexible
Conduits, click here.
APPLICATION:
-Meets NEC 350 Liquid
Tight Flexible Metal Conduit Type LFMC
-For a low smoke, low flame spread, zero halogen version, ask for Polyurethane
jacket Type L-IBC
-Consult factory for UL and CSA information
-ROHS and WEEE compliant
STANDARD COLORS:
Gray. Other colors
and jacketing materials are available upon request.
WORKING TEMPERATURES:
-55°C to 105°C
dBzSHIELD
Type BBS

Type
BBS is a hybrid of SBS and IBC. It utilizes the same bronze core and PVC
jacket as IBC, but gets further screening protection from a tinned copper
braid as found in the SBS product. Its range of shielding effectiveness
is from 126 dB @ 1MHz to 120dB @ 1GHz. Three sizes of BBS (3/4”,
1” and 2”) are now UL listed. Email
us to request information on compatible metallic brass (nickel-plated)
fittings available for this bronze conduit.
Email
us to request Type BBS data sheet.
For
dBzSHIELD Shielded Flexible Conduits Trade sizes, Dimensions, Bend Radius
and Weights in INCH-POUND measurements, click here.
For
dBzSHIELD Shielded Flexible Conduits Trade sizes, Dimensions, Bend Radius
and Weights in METRIC measurements, click here.
For
cutting instructions and conduit capacity chart, dBzSHIELD Shielded Flexible
Conduits, click here.
APPLICATION:
-Meets NEC 350 Liquid
Tight Flexible Metal Conduit Type LFMC
-For a low smoke, low flame spread, zero halogen version, ask for Polyurethane
jacket Type L-BBS
-Consult factory for UL and CSA information
-ROHS and WEEE compliant
STANDARD COLORS:
Black. Other colors
and jacketing materials available.
WORKING TEMPERATURES:
-55°C to 105°C
Type BBS is also used
as a component in a unique, patented wiring system solution called ZERO
GROUND HFES™. ZERO GROUND HFES™ addresses issues associated
with Adjustable Speed Drives in BJT, IGCT and IGBT technology(s), in conjunction
with motors, motor cables, as well as PE ground grids, and rapid rise
pulse phenomenon. ZERO GROUND HFES™ offers Safety & Reliability
by reducing High Frequency Ground Currents to Zero and by directing fault
currents away from hazardous locations. In addition, ZERO GROUND HFES™
extends motor life and significantly reduces unplanned downtime, due to
issues associated with ASD’s / motor installations.